CVE-2025-11566
CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker on the local network to gain access to the user account by performing an arbitra...
No known exploitation. EPSS puts it in the 43rd percentile. A vendor fix is available.
What to do
The vendor has published a fix. Version details are below where the sources state them.
What it is
From the CVE record
We strongly recommend the following industry cybersecurity best practices. * Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. * Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks. * Place all controllers in locked cabinets and never leave them in the “Program” mode. * Never connect programming software to any network other than the network intended for that device. * Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks. * Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation. * Minimize network exposure for all control system devices and systems and ensure that they are not accessible from the Internet. * When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). Recognize that VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand that VPNs are only as secure as the connected devices. For more information refer to the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/us/en/download/document/7EN52-0390/) document.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.5% chance of exploitation activity in the next 30 days, which ranks it in the 43rd percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
6 events over 225 days, from the signal feeds we watch.
- OpenVAS check added
- Patch availablepublished, weakness classified, att&ck mapped, record updated
Affected products
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorAV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L
Scored 7.3 by bdu.
How it is reached
- Access Vector NetworkExploitable remotely over the network
- Access Complexity LowNo special conditions required
Impact if exploited
- Confidentiality L
- Integrity L
- Availability L
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
- Credential AccessT1110Brute Forcehigh confidence
Sources
References in the record
- download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-315-01.pdf
- download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=sevd-2025-315-01.json
- download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-315-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-315-01.pdf
And 9 more references. See all after sign-in
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Schneider Electric, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI