Tenda FH1203
17 CVEs tracked. None of them is in CISA KEV.
This hub aggregates every CVE we track for Tenda FH1203, a product in the networking infrastructure space. Use it to gauge the current risk picture and drill into individual advisories.
Tenda FH1203 CVEs per month
| Month | CVEs |
|---|---|
| 2024-10 | 0 |
| 2024-11 | 0 |
| 2024-12 | 0 |
| 2025-01 | 0 |
| 2025-02 | 0 |
| 2025-03 | 0 |
| 2025-04 | 0 |
| 2025-05 | 0 |
| 2025-06 | 1 |
| 2025-07 | 0 |
| 2025-08 | 0 |
| 2025-09 | 0 |
| 2025-10 | 0 |
| 2025-11 | 0 |
| 2025-12 | 0 |
| 2026-01 | 0 |
| 2026-02 | 0 |
| 2026-03 | 0 |
| 2026-04 | 0 |
| 2026-05 | 0 |
| 2026-06 | 0 |
| 2026-07 | 0 |
| 2026-08 | 0 |
| 2026-09 | 0 |
Severity
How the 17 CVEs score on CVSS. Severity is not exploitation: KEV is counted above.
- Critical12
- High4
- Medium1
Latest CVEs
The 15 most recently published vulnerabilities affecting Tenda FH1203.
- CVE-2025-6113Tenda FH1203 AdvSetLanip fromadvsetlanip buffer overflow8.8
- CVE-2024-30606Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the page parameter of the fromDhcpListClient function.8.0
- CVE-2024-30598Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability in the security_5g parameter of the formWifiBasicSet function.6.5
- CVE-2024-30604Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the list1 parameter of the fromDhcpListClient function.7.5
- CVE-2024-30599Tenda FH1203 v2.0.1.6 has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.8.8
- CVE-2023-38930Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in th...9.8
- CVE-2023-38931Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1...9.8
- CVE-2023-38936Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were di...9.8
- CVE-2023-38940Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function.9.8
- CVE-2023-38933Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a sta...9.8
- CVE-2023-37701Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function.9.8
- CVE-2023-37706Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the entrys parameter in the fromAddressNat function.9.8
- CVE-2023-37704Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function.9.8
- CVE-2023-37703Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function.9.8
- CVE-2023-37707Tenda FH1203 V2.0.1.6 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function.9.8
Product grouping is registry-driven, with AI assist and human review. How it works