CVE Tools

Control Rte

14 CVEs tracked. None of them is in CISA KEV.

This hub aggregates every CVE we track for Control Rte, a product in the ics ot iot space. Use it to gauge the current risk picture and drill into individual advisories.

Control Rte CVEs per month

Oct 2024 to Sep 2026. Point at a month, or focus the strip and use the arrow keys.
Control Rte CVEs per month
MonthCVEs
2024-100
2024-110
2024-120
2025-010
2025-020
2025-030
2025-040
2025-050
2025-060
2025-070
2025-080
2025-090
2025-100
2025-110
2025-120
2026-010
2026-020
2026-030
2026-040
2026-050
2026-060
2026-070
2026-080
2026-090

Severity

How the 14 CVEs score on CVSS. Severity is not exploitation: KEV is counted above.

  • Critical429%
  • High750%
  • Medium321%

Latest CVEs

The 14 most recently published vulnerabilities affecting Control Rte.

  1. CVE-2018-25048Codesys Runtime Improper Limitation of a Pathname8.8
  2. CVE-2021-36763In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties.7.5
  3. CVE-2021-33485CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.9.8
  4. CVE-2021-29242CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove...7.3
  5. CVE-2020-15806CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation.7.5
  6. CVE-2020-12068An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.6.5
  7. CVE-2020-10245CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.9.8
  8. CVE-2020-7052CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition.6.5
  9. CVE-2019-18858CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.9.8
  10. CVE-2019-135423S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dere...6.5
  11. CVE-2019-9009An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.7.5
  12. CVE-2019-9008An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.8.8
  13. CVE-2019-13548CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service conditi...9.8
  14. CVE-2019-13532CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory ...7.5