CVE Tools

Simatic Wincc (Tia Portal)

17 CVEs tracked. None of them is in CISA KEV.

This hub aggregates every CVE we track for Simatic Wincc (Tia Portal), a product in the ics ot iot space. Use it to gauge the current risk picture and drill into individual advisories.

Simatic Wincc (Tia Portal) CVEs per month

Oct 2024 to Sep 2026. Point at a month, or focus the strip and use the arrow keys.
Simatic Wincc (Tia Portal) CVEs per month
MonthCVEs
2024-100
2024-110
2024-120
2025-010
2025-020
2025-030
2025-040
2025-050
2025-060
2025-070
2025-080
2025-090
2025-100
2025-110
2025-120
2026-010
2026-020
2026-030
2026-040
2026-050
2026-060
2026-070
2026-080
2026-090

Severity

How the 17 CVEs score on CVSS. Severity is not exploitation: KEV is counted above.

  • Critical16%
  • High847%
  • Medium847%

Latest CVEs

The 15 most recently published vulnerabilities affecting Simatic Wincc (Tia Portal).

  1. CVE-2019-19282A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2...7.5
  2. CVE-2019-10929A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 15...5.9
  3. CVE-2019-6577A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI ...5.4
  4. CVE-2019-6576A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI ...6.5
  5. CVE-2019-6572A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI ...9.1
  6. CVE-2019-10916A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 wi...8.8
  7. CVE-2019-10917A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 wi...5.5
  8. CVE-2019-10918A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 wi...8.8
  9. CVE-2018-13814A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP4...8.8
  10. CVE-2018-13812A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP ...7.5
  11. CVE-2018-13813A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP ...8.1
  12. CVE-2018-11454A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP...8.6
  13. CVE-2018-11453A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP...7.8
  14. CVE-2017-3737OpenSSL 1.0.2 (starting from version 1.0.2b) introduced an "error state" mechanism. The intent was that if a fatal error occurred during a handshake then OpenSSL would move into the error state and...5.9
  15. CVE-2017-6867A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) ...4.9

Product grouping is registry-driven, with AI assist and human review. How it works

We use analytics cookies to see which pages and articles actually help people. Decline and none of them run — the site works the same. What we store