CVE Tools

CVE-2026-3560

No known exploitation. EPSS puts it in the 43rd percentile. No fix published yet.

Published Updated Sources: CVE.org, NVD

What to do

No fixed build or workaround is published yet. Limit exposure and watch for a patch.

What it is

From the CVE record

Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS43rd
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

0.5% chance of exploitation activity in the next 30 days, which ranks it in the 43rd percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

4 events over 45 days, from the signal feeds we watch.

  1. Record updated
  2. Publishedweakness classified, att&ck mapped

Affected products

Technical detail

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Scored 8.8 by NVD.

How it is reached

  • Attack Vector AdjacentRequires access to the local network (e.g. same Wi-Fi, Bluetooth)
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability HighTotal denial of service — the component is completely unavailable

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Hue Bridge, not every advisory.

We use analytics cookies to see which pages and articles actually help people. Decline and none of them run — the site works the same. What we store