CVE Tools

CVE-2026-3559

No known exploitation. EPSS puts it in the 30th percentile. No fix published yet.

Published Updated Sources: CVE.org, NVD

What to do

No fixed build or workaround is published yet. Limit exposure and watch for a patch.

What it is

From the CVE record

Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS30th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

0.4% chance of exploitation activity in the next 30 days, which ranks it in the 30th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

3 events over 45 days, from the signal feeds we watch.

  1. Record updated
  2. Publishedweakness classified

Affected products

Technical detail

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

Scored 8.1 by NVD.

How it is reached

  • Attack Vector AdjacentRequires access to the local network (e.g. same Wi-Fi, Bluetooth)
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction NoneNo user interaction needed — fully automated exploitation

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity HighTotal loss of integrity — attacker can modify any data in the component
  • Availability NoneNo availability impact

Weaknesses

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Hue Bridge V2 Firmware, not every advisory.

We use analytics cookies to see which pages and articles actually help people. Decline and none of them run — the site works the same. What we store