CVE-2026-17583
Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check
No known exploitation. EPSS puts it in the 3rd percentile. A vendor fix is available.
What to do
The vendor has published a fix. Version details are below where the sources state them.
What it is
From the CVE record
Successful exploitation of this vulnerability could allow an attacker to modify .fsa/.hid output files, tampering with DNA data and resulting in inaccurate test results.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.1% chance of exploitation activity in the next 30 days, which ranks it in the 3rd percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
11 events over 21 days, from the signal feeds we watch.
- Patch availableworkaround available, record updated
- Patch availableworkaround available, record updated
- Patch availableworkaround available, published, weakness classified, record updated
Affected products
- abi prism 310 data collection softwareICS / OT / IoT / medical-device
- abi prism 3100\/3100-avant data collection softwareICS / OT / IoT / medical-device
- applied biosystems 3130 series data collection softwareICS / OT / IoT / medical-device
- applied biosystems 3500\/3500xl series data collection softwareICS / OT / IoT / medical-device
- applied biosystems 3730\/3730xl series data collection softwareICS / OT / IoT / medical-device
- applied biosystems seqstudio flex series instrument softwareICS / OT / IoT / medical-device
- applied biosystems seqstudio genetic analyzer data collection softwareICS / OT / IoT / medical-device
- genemapper id-xICS / OT / IoT / medical-device
- Applied Biosystems 3500/3500xL Series Data Collection Software
- Applied Biosystems 3730/3730xL Series Data Collection Software
- Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software
- Applied Biosystems SeqStudio Flex Series Instrument Software
- Applied Biosystems GeneMapper ID-X Software
- Applied Biosystems 3130 Series Data Collection Software
- ABI PRISM 3100/3100-Avant Data Collection Software
- ABI PRISM 310 Data Collection Software
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Scored 8.4 by NVD.
How it is reached
- Attack Vector LocalRequires local access to the vulnerable system (e.g. local login, malicious file)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
Sources
References in the record
- raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsma-26-216-01.json
- cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01
- cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
And 13 more references. See all after sign-in
In the news
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Thermofisher, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI