CVE-2024-52566
No known exploitation. EPSS puts it in the 13th percentile. A vendor fix is available.
What to do
The vendor has published a fix. Version details are below where the sources state them.
What it is
From the CVE record
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24233)
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.2% chance of exploitation activity in the next 30 days, which ranks it in the 13th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
6 events over 584 days, from the signal feeds we watch.
- OpenVAS check added
- Patch availablerecord updated
- Publishedweakness classified, att&ck mapped
Affected products
- Tecnomatix Plant SimulationICS / OT / IoT
- Teamcenter Visualization V14.2ICS / OT / IoT
- Teamcenter Visualization V14.3ICS / OT / IoT
- Teamcenter Visualization V2312ICS / OT / IoT
- Teamcenter Visualization V2406ICS / OT / IoT
- Tecnomatix Plant Simulation V2302ICS / OT / IoT
- Tecnomatix Plant Simulation V2404ICS / OT / IoT
And 1 more affected product. See all after sign-in
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Scored 7.8 by NVD.
How it is reached
- Attack Vector LocalRequires local access to the vulnerable system (e.g. local login, malicious file)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction RequiredA user must click a link, open a file, or perform some action
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
- Initial AccessT1190Exploit Public-Facing Applicationhigh confidence
- Privilege EscalationT1068Exploitation for Privilege Escalationhigh confidence
Sources
References in the record
- cert-portal.siemens.com/productcert/html/ssa-645131.html
- cert-portal.siemens.com/productcert/html/ssa-824503.html
- nvd.nist.gov/vuln/detail/CVE-2024-52566&
And 11 more references. See all after sign-in
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Siemens, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI