CVE-2024-29206
No known exploitation. EPSS puts it in the 36th percentile. No fix published yet.
What to do
No fixed build or workaround is published yet. Limit exposure and watch for a patch.
What it is
From the CVE record
An Improper Access Control could allow a malicious actor authenticated in the API to enable Android Debug Bridge (ADB) and make unsupported changes to the system. Affected Products: UniFi Connect EV Station (Version 1.1.18 and earlier) UniFi Connect EV Station Pro (Version 1.1.18 and earlier) UniFi Access G2 Reader Pro (Version 1.2.172 and earlier) UniFi Access Reader Pro (Version 2.7.238 and earlier) UniFi Access Intercom (Version 1.0.66 and earlier) UniFi Access Intercom Viewer (Version 1.0.5 and earlier) UniFi Connect Display (Version 1.9.324 and earlier) UniFi Connect Display Cast (Version 1.6.225 and earlier) Mitigation: Update UniFi Connect Application to Version 3.10.7 or later. Update UniFi Connect EV Station to Version 1.2.15 or later. Update UniFi Connect EV Station Pro to Version 1.2.15 or later. Update UniFi Access G2 Reader Pro Version 1.3.37 or later. Update UniFi Access Reader Pro Version 2.8.19 or later. Update UniFi Access Intercom Version 1.1.32 or later. Update UniFi Access Intercom Viewer Version 1.1.6 or later. Update UniFi Connect Display to Version 1.11.348 or later. Update UniFi Connect Display Cast to Version 1.8.255 or later.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.4% chance of exploitation activity in the next 30 days, which ranks it in the 36th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
3 events over 198 days, from the signal feeds we watch.
- Record updated
- Publishedweakness classified
Affected products
- UniFi Connect EV StationNetworking Infrastructure
- UniFi Connect EV Station ProNetworking Infrastructure
- UniFi Access G2 Reader Pro Networking Infrastructure
- UniFi Access Reader Pro Networking Infrastructure
- UniFi Access IntercomNetworking Infrastructure
- UniFi Access Intercom ViewerNetworking Infrastructure
- UniFi Connect DisplayNetworking Infrastructure
- UniFi Connect Display Cast Networking Infrastructure
Technical detail
CVSS 3.0 vector
Open in the CVSS calculatorCVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:L/A:N
Scored 2.2 by NVD.
How it is reached
- Attack Vector NetworkExploitable remotely over the network without any special conditions
- Attack Complexity HighRequires specific conditions like a race condition or non-default configuration
- Privileges Required HighRequires admin or elevated privileges
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality NoneNo confidentiality impact
- Integrity LowData modification is possible but limited in scope or consequence
- Availability NoneNo availability impact
Weaknesses
Sources
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for UniFi Connect EV Station, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI