CVE-2023-51605

No known exploitation. EPSS puts it in the 54th percentile. A vendor fix is available.

Published Updated Sources: CVE.org, NVD, BDU

What to do

The vendor has published a fix. Version details are below where the sources state them.

What it is

From the CVE record

Honeywell Saia PG5 Controls Suite XML External Entity Processing Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Honeywell Saia PG5 Controls Suite. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of XML files. Due to the improper restriction of XML External Entity (XXE) references, a crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. . Was ZDI-CAN-18644.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS54th
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

0.8% chance of exploitation activity in the next 30 days, which ranks it in the 54th percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

5 events over 313 days, from the signal feeds we watch.

  1. Patch availablerecord updated
  2. Publishedweakness classified, att&ck mapped

Affected products

And 1 more affected product. See all after sign-in

Technical detail

CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Scored 6.5 by NVD.

How it is reached

  • Attack Vector NetworkExploitable remotely over the network without any special conditions
  • Attack Complexity LowNo special conditions — the attack can be reliably reproduced
  • Privileges Required NoneNo authentication required — anyone can exploit this
  • User Interaction RequiredA user must click a link, open a file, or perform some action

Scope

  • Scope UnchangedImpact is limited to the vulnerable component itself

Impact if exploited

  • Confidentiality HighTotal information disclosure — all data in the component is compromised
  • Integrity NoneNo integrity impact
  • Availability NoneNo availability impact

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.