CVE-2018-8852
No known exploitation. EPSS puts it in the 79th percentile. A vendor fix is available.
What to do
The vendor has published a fix. Version details are below where the sources state them.
What it is
From the CVE record
Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session identifier.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
1.9% chance of exploitation activity in the next 30 days, which ranks it in the 79th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
6 events over 2248 days, from the signal feeds we watch.
- Patch availableworkaround available, record updated
- Publishedweakness classified, att&ck mapped
Affected products
Technical detail
CVSS 3.0 vector
Open in the CVSS calculatorCVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Scored 8.8 by NVD.
How it is reached
- Attack Vector NetworkExploitable remotely over the network without any special conditions
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction RequiredA user must click a link, open a file, or perform some action
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
- Defense EvasionT1550Use Alternate Authentication Materialmedium confidence
- Initial AccessT1078Valid Accountsmedium confidence
Sources
References in the record
- usa.philips.com/healthcare/about/customer-support/product-security
- securityfocus.com/bid/105194
- ics-cert.us-cert.gov/advisories/ICSA-18-242-01
And 19 more references. See all after sign-in
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.