From the CVE record
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. An attacker could use this vulnerability to compromise availability of the network connectivity. At the time of advisory publication no public exploitation of this vulnerability was known.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
1.5% chance of exploitation activity in the next 30 days, which ranks it in the 74th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
6 events over 2815 days, from the signal feeds we watch.
- OpenVAS check added
- Patch availablerecord updated
- Publishedweakness classified, att&ck mapped
Affected products
Technical detail
CVSS 3.0 vector
Open in the CVSS calculatorCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Scored 7.5 by NVD.
How it is reached
- Attack Vector NetworkExploitable remotely over the network without any special conditions
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality NoneNo confidentiality impact
- Integrity NoneNo integrity impact
- Availability HighTotal denial of service — the component is completely unavailable
Weaknesses
ATT&CK techniques
Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.
Sources
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.