CVE-2016-15058
Hirschmann HiLCOS Classic Platform Password Exposure via SNMP
No known exploitation. EPSS puts it in the 10th percentile. No fix published yet.
What to do
No fixed build or workaround is published yet. Limit exposure and watch for a patch.
What it is
From the CVE record
Hirschmann HiLCOS Classic Platform switches Classic L2E, L2P, L3E, L3P versions prior to 09.0.06 and Classic L2B prior to 05.3.07 contain a credential exposure vulnerability where user passwords are synchronized with SNMPv1/v2 community strings and transmitted in plaintext when the feature is enabled. Attackers with local network access can sniff SNMP traffic or extract configuration data to recover plaintext credentials and gain unauthorized administrative access to the switches.
In plain language
No plain-language summary for this CVE yet.
Exploitation
Where each signal puts this CVE on the scale from published to confirmed exploited.
- CISA KEV
Not in the catalog. CISA has not confirmed exploitation.
- Public exploits
No public exploit or proof of concept found in the sources we track.
- EPSS
0.2% chance of exploitation activity in the next 30 days, which ranks it in the 10th percentile of scored CVEs.
Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.
Lifecycle
4 events over 109 days, from the signal feeds we watch.
- Record updated
- Record updated
- Publishedweakness classified
Affected products
Technical detail
CVSS 3.1 vector
Open in the CVSS calculatorCVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Scored 8.1 by NVD.
How it is reached
- Attack Vector AdjacentRequires access to the local network (e.g. same Wi-Fi, Bluetooth)
- Attack Complexity LowNo special conditions — the attack can be reliably reproduced
- Privileges Required NoneNo authentication required — anyone can exploit this
- User Interaction NoneNo user interaction needed — fully automated exploitation
Scope
- Scope UnchangedImpact is limited to the vulnerable component itself
Impact if exploited
- Confidentiality HighTotal information disclosure — all data in the component is compromised
- Integrity HighTotal loss of integrity — attacker can modify any data in the component
- Availability NoneNo availability impact
Weaknesses
Sources
Watch the software you run.
My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.
We'll flag the next CVE, public exploit or patch for Belden, not every advisory.
A free account adds
- The full version matrix and every affected product
- Exploit links, proofs of concept and Metasploit modules
- Email alerts for the products you watch
- The same data over REST API, MCP and CLI