CVE Tools

CVE-2013-5021

No known exploitation. EPSS puts it in the 81st percentile. No fix published yet.

Published Updated Sources: CVE.org, NVD

What to do

No fixed build or workaround is published yet. Limit exposure and watch for a patch.

What it is

From the CVE record

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

In plain language

No plain-language summary for this CVE yet.

Exploitation

Where each signal puts this CVE on the scale from published to confirmed exploited.

EPSS81st
CISA KEV

Not in the catalog. CISA has not confirmed exploitation.

Public exploits

No public exploit or proof of concept found in the sources we track.

EPSS

2.1% chance of exploitation activity in the next 30 days, which ranks it in the 81st percentile of scored CVEs.

Exploit Prediction Scoring System, FIRST.org. A probability, not a confirmation.

Lifecycle

4 events over 4649 days, from the signal feeds we watch.

  1. Record updated
  2. Publishedweakness classified, att&ck mapped

Affected products

And 1 more affected product. See all after sign-in

Technical detail

AV:N/AC:M/Au:N/C:C/I:C/A:C

Scored 9.3 by NVD.

How it is reached

  • Access Vector NetworkExploitable remotely over the network
  • Access Complexity MediumSome conditions must be met
  • Authentication NoneNo authentication required

Impact if exploited

  • Confidentiality CompleteAll information is disclosed
  • Integrity CompleteAll data can be modified
  • Availability CompleteTotal shutdown of the affected resource

Weaknesses

ATT&CK techniques

Mapped from the weaknesses above (CWE to ATT&CK), not observed in attacks.

Sources

Watch the software you run.

My Stack ranks new CVEs for your products by real-world exploitation, so the next serious one reaches you without reading every advisory.

We'll flag the next CVE, public exploit or patch for Labview, not every advisory.

We use analytics cookies to see which pages and articles actually help people. Decline and none of them run — the site works the same. What we store